datasheet:rp2040
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
datasheet:rp2040 [2025/04/16 21:19] – [Clocks] lars | datasheet:rp2040 [2025/04/16 21:54] (current) – [Clocks] lars | ||
---|---|---|---|
Line 83: | Line 83: | ||
ROSC : Ring Oscillator (1.8 - 12 MHz) | ROSC : Ring Oscillator (1.8 - 12 MHz) | ||
- | XOSC : Crystal Oscillator | + | XOSC : Crystal Oscillator |
System PLL : (from XOSC) | System PLL : (from XOSC) | ||
Line 91: | Line 91: | ||
**__Provided clocks:__** | **__Provided clocks:__** | ||
- | clk_ref = reference clock (Watchdog + Timers) | + | clk_ref = reference clock (runs from ROSC can be switched to XOSC)(Watchdog + Timers) |
clk_sys = sytem clock (max 200 MHz) (Processors, | clk_sys = sytem clock (max 200 MHz) (Processors, | ||
- | clk_peri (UART + SPI) | + | clk_peri |
- | clk_usb = 48 MHz (USB | + | clk_usb = 48 MHz (USB) |
clk_adc = 48 MHz (ADC) | clk_adc = 48 MHz (ADC) |
datasheet/rp2040.1744838350.txt.gz · Last modified: by lars